14 completed jobs from this business’s service history, most recent first. Every item has a source and a date. Customer details are never shown.
Packaged rooftop unit replacement
A failed packaged rooftop unit serving a single-storey retail building was removed and replaced. The curb adapter was refitted, the condensate run was re-pitched, and the unit was commissioned and balanced the same day.
Complete system installation
A residential split system at end of life was replaced with a matched high-efficiency air handler and condenser. The line set was replaced, the plenum was rebuilt to fit, and static pressure was verified before handover.
Evaporator coil replacement
A heavily fouled evaporator coil was documented, removed and replaced. The return plenum was cleaned and sealed, and airflow was measured against the original reading to confirm the improvement.
Compressor contactor and capacitor repair
A condenser that would not start on call was diagnosed to a pitted contactor and a failed run capacitor. Both were replaced and amp draw was confirmed within specification before the technician left.
No photograph is published for this job.
Ductwork sealing and static pressure correction
Supply trunk leakage was measured and sealed at every accessible joint. Static pressure came down enough to bring the blower back inside its rated range without changing equipment.
Heat exchanger inspection and condemnation
A furnace reported as intermittently shutting down was inspected with a combustion analyser and a borescope. A cracked heat exchanger was found, the unit was tagged and shut off, and the finding was documented for the owner.
No photograph is published for this job.